Growmax Water Industrial Osmosis High Pro 10 to 75 m³/day – Custom Reverse Osmosis Plants
Growmax Water Industrial Osmosis High Pro 10 to 75 m³/day – Custom Reverse Osmosis Plants
-
Range: High Pro industrial
-
Capacities: 10 to 75 m³/day (10 models)
-
Technology: High-rejection reverse osmosis
-
Scope: Pre-filtration, UF, osmosis, and disinfection
-
Supply: Made to order, custom quoted
-
Weight: Estimated 250 kg (no official data)
Discover the benefits of the PRO CLUB
Discounts of up to -12%, priority shipping and more.
Easy returns within 15 days
No questions asked
Description
- 🚨 Made to order: Custom engineering project. Quoted and sized according to your water and installation; consult us before purchasing.
- 📊 From 10 to 75 m³/day: Ten capacities to cover 10,000 to 75,000 liters per day.
- 💧 Industrial reverse osmosis: Skid, high-pressure pumping, membranes, and control panel.
- ♻️ Complete plant: Pre-filtration, ultrafiltration, osmosis, and disinfection in a single project.
- 🧪 Only osmosis lowers EC: If your problem is chlorine and not hardness, a carbon filter is enough.
Tell us your water analysis and your consumption: we size the plant with you.
Full description
⚠️ MADE-TO-ORDER ITEM — CUSTOM ENGINEERING PROJECT
Industrial osmosis plants are not off-the-shelf products with stock. Each system is quoted and sized to order based on your water analysis, actual flow rate, and installation conditions. The amount shown is a reference price for the standard configuration: contact us before purchasing to confirm the sizing and scope of supply. We do not provide delivery times, as they depend on each project and are confirmed in the quote.
Growmax Water High Pro Industrial Osmosis: 10 to 75 m³/day
The Growmax Water High Pro range consists of industrial reverse osmosis plants for facilities that have far outgrown the scale of a commercial unit. They produce 10 to 75 m³/day of water, or 10,000 to 75,000 liters per day, and include a frame, high-pressure pump, membrane housings, and control panel.
This is the point at which osmosis ceases to be an add-on and becomes a water treatment installation: the raw water, prefiltration, reject water, storage, and downstream distribution must all be carefully considered. That is why we work on a project basis.
What a High Pro project includes
- Prefiltration: solids removal, carbon filtration, and dechlorination to protect the membranes.
- Ultrafiltration when required by the raw water.
- Industrial reverse osmosis: frame with high-rejection membranes, high-pressure pump, and instrumentation.
- Disinfection of the produced or stored water.
- Complete turnkey plants, including storage tanks and pressure systems.
Available capacities
The range is available in ten sizes: 10, 15, 20, 25, 30, 40, 45, 50, 60, and 75 m³/day. The choice depends not only on peak consumption but also on the planned operating hours, available storage volume, and incoming water quality. The same consumption can be met by a smaller unit operating longer hours to fill a tank, or by a larger unit operating on demand.
How it is sized
To provide a quote, we require at least an analysis of the incoming water (TDS or conductivity, hardness, iron, chlorine, silica), the flow rate and daily volume you need, the pressure and flow rate available at the connection, the average water temperature, and the site conditions (space, electrical supply, and drainage for reject water). Using this data, we determine the number of membranes, pumping requirements, prefiltration, and recovery.
Reject water is not a minor detail
All osmosis systems produce reject water. Standard household and commercial units operate at an approximate 2:1 ratio for water with 500 ppm TDS at 25°C. In an industrial plant, the recovery percentage is adjusted during the design phase, but the reject water volume remains high in absolute terms: drainage must be planned, and it is worth investigating whether that water can be reused.
Do you really need osmosis?
Before making the switch, it is important to be clear: carbon filters such as the Pro Grow 2000 L/h or the Super Grow 800 L/h remove chlorine, chloramines, and sediment but do not lower the EC. Only reverse osmosis reduces the EC. If your problem is chlorine rather than hardness, an osmosis plant is an unnecessary expense.
The previous step: the commercial range
If your consumption is below 10 m³/day, the commercial range is probably right for you. The step immediately below this series is the Grow Max 3000 L/day, and below that are the Mega Grow 1000, the Max Pump 700, the Power Grow 500, and the Grow MiniMax 75.
Related products
- Industrial Osmosis GMP-S 12 to 108 m³/day — the other industrial range, for even higher flow rates.
- Grow Max 3000 L/day — the next commercial step down.
- 10" and 20" deionization kit — the final stage for achieving 000 ppm.
- Growmax Water spare parts and filters and osmosis tubing.
Warranty
At GrowIndustry we only work with proven quality products and trusted brands.
Every item goes through a check before shipping to make sure it arrives in perfect condition and ready to use.
Your satisfaction is our priority.
How to use
1. First and foremost, consult us: these plants are quoted and sized to order; they are not supplied as off-the-shelf catalog items.
2. Gather a complete analysis of the feed water: conductivity or TDS, hardness, iron, silica, and free chlorine.
3. Determine your actual consumption: daily volume, peak flow rate, and expected operating hours.
4. Check your connection: available pressure and flow rate, electrical supply, and drainage for the reject water.
5. With this data, we determine the configuration: number of membranes, pumping, pre-filtration, and target recovery.
6. Once operational, follow the maintenance plan: monitor pressures, clean the membranes, and record the permeate conductivity.

Growmax Water Industrial Osmosis High Pro 10 to 75 m³/day – Custom Reverse Osmosis Plants
Join our exclusive club for regular customers and start enjoying unbeatable prices, VIP service and premium support for your grows.
Increasing discounts
Save an extra -3% to -12%
Free shipping before
From €39 for Bronze and no minimum for Platinum (up to 10 kg)
Fast deliveries
With free, discreet shipping
Extended warranty
Up to 3 years
Frequently asked questions
-
It is a made-to-order item and a custom engineering project, not a catalogue product held in stock. The amount you see is a guide price for the standard configuration: get in touch before buying so we can confirm the sizing and the scope of supply.
-
It runs from 10 to 75 m³/day, that is from 10,000 to 75,000 litres a day, in ten sizes: 10, 15, 20, 25, 30, 40, 45, 50, 60 and 75 m³/day. The choice does not depend on peak consumption alone, but also on the hours of operation and the storage volume available.
-
Pre-filtration with solids removal, carbon filtration and dechlorination, ultrafiltration where the raw water calls for it, the industrial reverse osmosis system with a high-rejection membrane rack, high-pressure pump and instrumentation, and disinfection of the product water. We also build turnkey plants with tanks and pressure sets.
-
As a minimum, an analysis of the feed water with TDS or conductivity, hardness, iron, chlorine and silica, the daily flow rate and volume you need, the pressure and flow available at the mains connection, the average water temperature and the site conditions: space, power supply and a drain for the waste water.
-
Every reverse osmosis system produces waste water. The reference domestic and commercial units work at a ratio of roughly 2:1 on water of 500 ppm TDS at 25 degrees. On an industrial plant the recovery rate is set during the design stage, but the volume of waste water is still high.
-
We do not state lead times on the product page, because they depend on each project and are confirmed in the quote. Write to us Monday to Friday from 10:00 to 19:00 and we will look at your case to give you a realistic scope and timeframe.