Hanna pH 7.01 Calibration Solution – Calibration Liquid for pH Meters
Hanna pH 7.01 Calibration Solution – Calibration Liquid for pH Meters
-
Type: pH buffer solution
-
Value: 7.01 pH at 25 °C
-
Accuracy: ±0.01 pH
-
Packaging: Airtight with tamper-evident seal
-
Formats: 230 ml bottle or 25 x 20 ml sachets
-
References: HI7007M and HI70007P
Discover the benefits of the PRO CLUB
Discounts of up to -12%, priority shipping and more.
Easy returns within 15 days
No questions asked
Description
- 🧪 pH 7.01 buffer: The reference neutral point at 25 °C with which all calibration begins.
- 🎯 Accuracy ±0.01 pH: Standard tolerance to reliably adjust any pH meter.
- 🔒 Airtight container: Tamper-evident seal and color-coded label to identify it instantly.
- 🗓️ Batch and expiration: Printed on the label so you always know what you are calibrating with.
- 📦 Two formats: 230 ml bottle or box of 25 single-dose 20 ml sachets.
The Hanna Instruments pH 7.01 buffer, the mandatory starting point for properly calibrating your meter.
Full description
Hanna pH 7.01 Calibration Solution – Calibrating Liquid for pH Meters
Hanna Instruments pH 7.01 Calibration Solution is the neutral buffer used to start any pH meter calibration: it is the point that sets the electrode's zero before adjusting the slope with an acidic or alkaline buffer. Glass electrodes drift with use, and that drift is not visible until the reading is compared with a known value. Regularly calibrating using this solution is the easiest way to ensure that the pH you see on the screen is the actual pH in your tank or substrate.
Key Features
- Reference neutral point: pH 7.01 value at 25 °C, the first point of any calibration.
- Standard accuracy ±0.01 pH: sufficient margin to reliably adjust home and professional meters.
- Color-coded label: allows you to identify the buffer at a glance and prevents confusing it with pH 4.01.
- Airtight container with tamper-evident seal: the solution arrives without value alterations.
- Two formats: 230 ml bottle for the workbench and box of 25 single-dose 20 ml sachets for calibrating anywhere.
Technical Specifications
- Solution type: pH 7.01 buffer solution
- pH value: 7.01 at 25 °C
- Accuracy: standard ±0.01 pH
- Identification: batch number and expiration date on the label
- Container: airtight, with tamper-evident seal
- Labeling: color-coded
- Formats: 230 ml bottle (HI7007M) or box of 25 single-dose 20 ml sachets (HI70007P)
- Brand: Hanna Instruments
Available Formats
- 230 ml Bottle (HI7007M): classic laboratory format for daily calibration; a small amount is poured into a clean beaker and discarded after each use.
- Box of 25 20 ml Sachets (HI70007P): 25 sealed single-use doses, the cleanest and most portable option for calibrating directly in the grow room.
Warranty
At GrowIndustry we only work with proven quality products and trusted brands.
Every item goes through a check before shipping to make sure it arrives in perfect condition and ready to use.
Your satisfaction is our priority.
How to use
1. Check the label to ensure the solution is within its expiration date and that the seal is intact.
2. Rinse the electrode with distilled or deionized water and remove excess water without rubbing the glass membrane.
3. Pour a small amount into a clean glass or open a single-dose packet; never put the electrode in the bottle.
4. Immerse the electrode far enough to cover the bulb and reference junction and shake gently to remove bubbles.
5. Wait for the reading to stabilize and confirm the 7.01 pH point; then continue with the 4.01 pH buffer if your meter supports two-point calibration.
6. Discard the used solution, do not reuse it or return it to the container, and rinse the electrode before measuring your sample.

Hanna pH 7.01 Calibration Solution – Calibration Liquid for pH Meters
Join our exclusive club for regular customers and start enjoying unbeatable prices, VIP service and premium support for your grows.
Increasing discounts
From 2% to 10% on every purchase depending on your level
Free shipping before
From €39 for Bronze and no minimum for Platinum (up to 10 kg)
Fast deliveries
Free discreet packaging as a PRO CLUB member
Extended warranty
Up to 90 days to return depending on your level
Frequently asked questions
-
Because it is the neutral buffer that sets the electrode's zero before the slope is adjusted with an acid or alkaline buffer. That is why it is the first point in every calibration of a pH meter.
-
Glass electrodes drift with use and that drift is invisible until you compare the reading against a known value. Calibrating regularly with this solution is the simplest way to make sure the pH on the display is the one really present in your tank or substrate.
-
The label is colour-coded, so you can identify the buffer at a glance. It also has the batch number and the expiry date printed on it so you always know what you are using.
-
It has a standard accuracy of ±0.01 pH, with a value of 7.01 at 25 °C. That is more than enough margin to adjust both domestic and professional meters with confidence.
-
The 230 ml bottle (HI7007M) is the classic laboratory format for calibrating daily from the workbench. The box of 25 sachets of 20 ml (HI70007P) are sealed single-use doses, the cleanest and most portable option for calibrating right in the grow room.
-
Yes, the container is airtight and has a tamper-evident seal, so the solution arrives with no change in its value. That is an important detail in a calibration standard, because the reliability of all your readings depends on it.